SPA or SPB Series Certified Metallic Stopping Plugs provide a method of filling unused entries in Ex equipment, maintaining Flameproof Exd method of explosion protection and IP54 for IEC type applications. Class I, Division 1 and NEMA 3 for NEC/CEC type applications.
SPA Type - Externally accessible hexagon recess
SPB Type - Internally accessible hexagon recess
 
CERTIFICATIONCENELEC
SIRA99ATEX1113 II 2DG E Ex d IIC

CSA / A Ex
Class I, Zone 1, Ex d IIC
Class I, Division 1 & 2 ABCD
Class II EFG, Class III

IECEx Ex d IIC
IECEx SIR 05.0042U
INGRESS
PROTECTION
IP54, CSA Enclosure Type (NEMA) 3
IMPACT RESISTANCE7Nm
OPERATING TEMPERATURES-100ºC to +600ºC
MATERIALS
Brass CZ121 (SPAB, SPBB)
316 Stainless Steel (SPAS, SPBS)
Aluminium Alloy (SPAA, SPBA)
THREADSISO Metric; ET; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
PLATINGZinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)
EXAMPLE PART NUMBERSample: SPAB/NP/M20
SPA - Stopping Plug type (Externally accessible hexagon recess)
B - Body material (Brass)
NP - Nickel plating
M20 - Male thread size
SIZES AVAILABLE AND DIMENSIONAL REFERENCES
MetricDim RefNPTDim RefISO PipeDim RefPGDim Ref
M16B    7A
M20C1/2"D1/2"F9B
M25C3/4"D3/4"F11C
M32C1”E1”H13.5C
M40C1*1/4"E1*1/4"H16C
M50C1*1/2"E1*1/2"H21C
M63C2”E2”H29C
M75C2*1/2"G2*1/2"H36C
M80 x 2.0G3”G3”H42C
M85 x 2.0G3*1/2"G  48C
M90 x 2.0G4”G    
M100 x 2.0G      
DIMENSIONS
Dimension ReferenceABCDEFGH
Hex Socket A/F6.08.010.010.010.010.010.010.0
Length (min)16.017.017.014.016.018.022.025.0
All Dimensions are in Millimetres
NOTES:
  • Full installation instructions are supplied with stopping plugs, the instructions must be read prior to installation and adhered to in full
  • Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
  • For Flameproof Exd applications the female thread into which the stopping plug is to be fitted must comply with clause 5.3 of EN 50018:2000 (clause 5.3 IEC 79-1)
  • For NEC/CEC Explosion Proof applications an engagement of at least 8 full threads must be achieved for parallel threads and 5 full threads must be achieved for tapered threads

 

 

中国区分销商:
上海颐品自动化科技有限公司

Shanghai Epin Automation Co.,Ltd.

Website:www.epinautomation。。com
:sales@epinautomation.com
*:

因为专业,所以放心!

上一篇:卧式暗装风机盘管机组产品选用要点 下一篇:消防排烟风机主管技术工程师应在总平面图上制作出管线及单线
热线电话 在线询价
提示

请选择您要拨打的电话: