英国Peppers防爆密封接头Peppers cable Gland

上海颐品自动化,:

Including type No’s:
A*LDS*F
 2   S 
 3   A 
A2LDSF type glands provide two pull resistant seals on the outer sheath of any cable. A2LDSF type glands maintain Flameproof Exd and Increased Safety Exe methods of explosion protection and IP66, IP68 to 25 metres. An integral ‘O’ ring entry thread seal is fitted to metric versions as standard.
COMPLIANCE STANDARDEN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0,
EN 61241-1, IEC 60079-0, IEC 60079-1,
IEC 60079-7, IEC 61241-0 & IEC 61241-1
CERTIFICATION ATEX II 2 GD, E Exd            IIC / E Exe II
 GOST R-Exd IICU/Exe            IIU
 CSA Exd IIC/Exe II 4X,            Class 1, Zone 1
 IECEx Ex d IIC / Ex e II
 NEPSI Exd IIC / Exe II
CERTIFICATESIRA 01ATEX1272X - Ex Notified Body No. 0518
POCC GB MJL14.B00030
CSA 1356011
IECEx SIR 07.0096X
NEPSI GYJ06186X
GLAND MARKINGMJL14 Peppers GU15 3BT UK A2LDSF/20/M20
CA Sira 01ATEX1272X Ex II 2 GD EExd IIC/EExe II
IEC Ex SIR 07.0096X Exd IIC/Exe II/Ex tD A21 IP68
APPLICATION
EExd Equipment
A2LDSF type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2

Gas Group

Internal Ignition Source

Enclosure Volume

Which Zone

Use A2L**F Gland

IIC, IIB, IIA

NO

Any

Zone 1 or 2

YES

IIB, IIA

YES

Any

Zone 2

YES

IIB, IIA

YES

2 litres or less

Zone 1

YES


EExe Equipment

Other Equipment
Gas Group II, Zones 1 and 2Ignitable Dust, Zones 21 and 22
INGRESS
PROTECTION
IP66 and IP68 @ 25 metres, Enclosure Type 4X
MATERIALSBrass CZ121 ((A2LDSF)
316 Stainless Steel (A2LDSSF)
Aluminium Alloy (A2LDSAF)

Outer sheath seal material:
Standard (A2LDSF) Neoprene, black. Option (A3LDSF) Silicone, white.
Integral entry thread seal: Nitrile is supplied with neoprene outer seal version. Silicone is supplied with silicone
outer seal version.
VARIATIONSFor lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (A4LDSF); 316 Stainless Steel (A4LDSSF)
OPTIONSTHREADSISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
SEALSExtended operating temperature -60°C to +180°C, halogen free versions:
Brass (A3LDSF); 316 Stainless Steel (A3LDSSF); Aluminium (A3LDSAF)
PLATINGZinc (ZP); Nickel (NP); Tin (TP); Electroless Nickel (EN)
OPERATING TEMPERATURESStandard Seals -20ºC to +85ºC
Silicone Seals - 60ºC to +180ºC
ACCESSORIESLocknut - Brass (ACBLN); 316 Stainless Steel (ACSLN); Aluminium (ACALN)
Earth Tag - Brass (ACBET), 316 Stainless Steel (ACSET); Aluminium (ACAET)
IP Washer - Nylon (ACNSW); Red Fibre (ACFSW)
Serrated Lock Washer - 316 Stainless Steel (ACSSW), Galvanised Steel (ACGSW)
Shroud - PVC (ACSPVC); PCP (ACSPCP); Low Smoke Zero Halogen (ACSSIO)
EXAMPLE PART NUMBERSample: A2LDSF /ZP/20S/M20
A2LDSF:
A*LDSF - Gland type and body material (Brass)
*2**** - Seal material (Neoprene)
ZP - Zinc plating
20s - Gland size with regards to cable acceptance range
M20 - Entry thread
Gland Size
Entry Threads
MetricNPT/BSP
Entry
Thread
Length
[B]
Max
Across
Corners
[A]
Max
Protrusion
Length
Gland Seal Range
Cable Outer Sheath [D]
MinMax
Shroud Size
16M201/2" or
3/4"
1628.066.04.08.4L24
20sM201/2" or
3/4"
1628.066.07.211.7L24
20M201/2" or
3/4"
1629.766.09.614.0L27
25M253/4" or
1"
1639.666.013.520.0L36
32M321" or
1*1/4"
1645.166.019.526.3L41
40M401*1/4" or
1*1/2"
1655.974.023.032.2L51
50sM501*1/2" or
2"
1671.574.028.238.2L65
50M502”1671.574.033.244.1L65
63sM632" or
2*1/2"
1988.074.039.350.1L80
63M632*1/2"1988.074.046.756.0L80
75sM752*1/2" or
3"
1999.074.052.362.0L90
75M753”1999.074.058.168.0L90
80M80 x 23" or
3*1/2"
25115.2100.062.372.0L104
85M85 x 23" or
3*1/2"
25115.2100.069.178.0L104
90M90 x 23*1/2" or
4"
25125.71050.074.184.0L114
100M100 x 23*1/2" or
4"
25125.7100.082.090.0L114
All Dimensions are in Millimetres
NOTES:
  • Suitable only for fixed installations. The cable must be clamped near the gland to prevent pulling and twisting
  • Gland Size does not necessarily equate to the entry thread size
  • Integral entry thread seal option is not available for glands with tapered entry threads. IP washers can be supplied if required
  • Please note that dimensions (A) and (B) may differ for glands with non-Metric entry threads. Please refer to our thread data tables for specific dimensions
  • Unless otherwise stated ISO Metric entry threads have a 1.5mm pitch
  • For Flameproof Exd applications the female thread into which the gland is to be fitted must comply with clause 5.3 of EN 50018:2000 (clause 5.3 IEC 79-1) and an engagement of at least 5 full threads must be achieved for parallel threads and should be achieved for tapered threads
  • Where A2LF type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system
  • The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/ installation
  • Full assembly instructions are supplied with glands, the instructions must be read prior to installation and adhered to in full
  • In order to maintain an IP rating greater than IP54, when used in a clearance hole, a suitable IP washer is required.
  • Peppers supplies cable glands with parallel entry threads which conform to the flameproof threaded joint requirements of IEC 60079-1 and other equivalent standards. They usually incorporate a thread run out according to the available machining techniques, and will not have a full-form thread for the entire length. Peppers will not be held responsible for clients’ installations where this has not been taken into account.

 

 

中国区分销商:
上海颐品自动化科技有限公司

Shanghai Epin Automation Co.,Ltd.

Website:www.epinautomation。。com
:sales@epinautomation.com
*:

因为专业,所以放心!

上一篇:卧式暗装风机盘管机组产品选用要点 下一篇:消防排烟风机主管技术工程师应在总平面图上制作出管线及单线
热线电话 在线询价
提示

请选择您要拨打的电话: