英国Peppers防爆密封接头Peppers cable Gland

上海颐品自动化,:

Including type No’s:
A2LCFBF
 3 CMS 
    A 
“A*LCF” type glands, certified Flameproof Ex d, Increased Safety Ex e & Restricted Breathing Ex nR are suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. They provide a controlled pull resistant environmental displacement seal on the cable outer sheath, minimising damage to cables that exhibit “cold flow” characteristics. The gland maintains IP66 & IP68 to 25 metres and is deluge proof without the use of an additional seal or deluge boot. It is supplied with an IP O-ring seal as standard on metric entry threads. The gland features a female conduit connection thread as standard with an option for a male connection thread.
 
COMPLIANCE STANDARDEN 60079-0, EN 60079-1, EN 60079-7,
EN 60079-15, EN 61241-0, EN 61241-1
IEC 60079-0, IEC 60079-1, IEC 60079-7,
IEC 61241-0, IEC 61241-1 & IEC 60529
CERTIFICATIONATEX II 2 GD Ex d IIC / Ex e II / Ex tD A21
II 3 GD Ex nR II
IECEx Ex d IIC / Ex e II / Ex tD A21
GOST-R Ex d IICU / Ex e IIU
CSA Ex d IIC / Ex e II Class I Zone 1
Class I Division 2, Groups A, B, C & D
Class II Division 2, Groups E, F & G
Class III, Enclosure Types 3, 4 & 4X
NEPSI Ex d IIC / Ex e II
INMETRO BR - Ex d IIC / Ex e II / Ex nR II / Ex tD A21
ABS 1-1-4/7.7, 4.8-3/1.7, 4-8-3/13 and 4-8-4/27.5
MODU Rules 4-3-3/9
LLOYD’S Enclosure Systems (Part 1B)
RMRS Part XI of Rules for sea-going ships (ed.2008)
CERTIFICATE NO.ATEX SIRA 01ATEX1272X & SIRA 09ATEX1221X IECEx SIR 07.0096X
GOST-R POCC GB.06.BOO853
CSA CSA 1356011
NEPSI GYJ06186X
INMETRO NCC 5879/09 X
ABS 09-LD463991-PDA
LLOYD’S 10/00056
RMRS 09.00784.011
IP RATINGIP66 & IP68 (25 metres - 30 minutes), NEMA 4X & DTS01 1991
APPLICATION
EExd Equipment
A2L**F type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2

Gas Group

Internal Ignition Source

Enclosure Volume

Which Zone

Use A2L**F Gland

IIC, IIB, IIA

NO

Any

Zone 1 or 2

YES

IIB, IIA

YES

Any

Zone 2

YES

IIB, IIA

YES

2 litres or less

Zone 1

YES


EExe Equipment

Other Equipment
Gas Group II, Zones 1 and 2Ignitable Dust, Zones 21 and 22
MATERIALSBrass, Stainless Steel or Aluminium
OPTIONSTHREADSISO Metric; NPT; NPS; ISO Pipe Thread (BSP Taper, BSP Parallel); PG
SEALSExtended operating temperature -60ºC to +180ºC, halogen free versions:
Brass (A3L**F); 316 Stainless Steel (A3L**SF)
PLATINGZinc (ZP); Nickel (NP)
OPERATING TEMPERATURESStandard Seals -20ºC to +85ºC
Silicone Seals -60ºC to +180ºC
ACCESSORIESLocknut Brass (ACBLN) / Stainless Steel (ACSLN)
Earth tag: Brass (ACBET) / Stainless Steel (ACSET)
IP Washers: Nylon (ACNSW) / Fibre (ACFSW)
Serrated Washers: Stainless Steel (ACSSW)
EXAMPLE PART NUMBERINGSample: A2LCFBF050NPT/NP/20/M20
A: Type of gland featuring controlled displacement sealing
2: Neoprene Seals (2) - Silicone (3)
L: Peppers Lightweight Design
CF: Female Conduit Connection Thread (CF) / Male Thread Option (CM)
B: Brass (B) / Stainless Steel (S) / Aluminium (A)
F: Multiple Certification
050NPT: 1/2”NPT Female Conduit Connection Thread
NP: Nickel Plated (NP) - Zinc Plated (ZP)
20: Gland shell size
M20: M20 x 1.5 Entry Thread
Gland Size
Entry Threads
MetricNPT/BSP
Entry Thread Length
[B]
Max Across Corners
[A]
Gland Seal Range
Cable Outer Sheath [D]
MinMax
Conduit Connector
NPTISO
16M20 x 1.51/2" or 3/4"1628.04.08.41/2" or 3/4"M20 x 1.5
20sM20 x 1.51/2" or 3/4"1628.07.211.71/2" or 3/4"M20 x 1.5
20M20 x 1.51/2" or 3/4"1633.09.414.01/2" or 3/4"M20 x 1.5
25M25 x 1.53/4" or 1"1641.413.520.03/4" or 1"M25 x 1.5
32M32 x 1.51" or 1*1/4"1650.619.526.31" or 1*1/4"M32 x 1.5
40M40 x 1.51*1/4" or 1*1/2"1660.523.032.21*1/4" or 1*1/2"M40 x 1.5
50sM50 x 1.51*1/2" or 2"1671.528.138.21*1/2" or 2"M50 x 1.5
50M50 x 1.52”1671.533.144.12”M50 x 1.5
63sM63 x 1.52" or 2*1/2"1988.039.250.12" or 2*1/2"M63 x 1.5
63M63 x 1.52*1/2"1988.046.756.02*1/2"M63 x 1.5
75sM75 x 1.52*1/2" or 3"1999.052.162.02*1/2" or 3"M75 x 1.5
75M75 x 1.53”1999.058.068.03”M75 x 1.5
80M80 x 23” or 3 1/2”25115.262.272.03” or 3 1/2”M80 x 2
85M85 x 23” or 3 1/2”25115.269.078.03” or 3 1/2”M85 x 2
90M90 x 23 1/2” or 4”25125.774.084.03 1/2” or 4”M90 x 2
100M200 x 23 1/2” or 4"25125.782.090.03 1/2” or 4"M200 x 2
All Dimensions are in Millimetres
NOTES:
  • Gland size does not necessarily equate to the entry thread size. Gland size 16 is also available with an M16 x 1.5 entry thread.
  • The IP O-ring seal is only available on metric entry threads. IP washers can be supplied for tapered entry threads.
  • Please ensure that the IP O-ring is not used in conjunction with a flat IP washer.
  • Dimensions (A) & (B) may differ for glands with non metric entry threads. Please refer to our “Thread Reference Tables” for specific dimensions.
  • Where glands are fitted into non-metallic Ex e enclosures they must be included within the earth circuit of the system.
  • The user should seek expert advice if intending to combine flammable and combustible dust in one environment/installation.
  • Where A2LF type glands are fitted into non-metallic Increased Safety Exe enclosures they must be included within the earth circuit of the system
  • The user should seek expert advice if intending to combine flammable gases and combustible dusts in one environment/ installation
  • Assembly instructions must be read prior to installation and adhered to in full.
  • Peppers supplies cable glands with parallel entry threads that conform to the flameproof threaded joint requirements of IEC/EN 60079-1 and other equivalent standards. They usually incorporate a thread run out according to the available machining techniques and will not have a full form thread for the entire length. Peppers will not be held responsible for clients’ installations where this has not been taken into account.
  • To maintain the specified IP rating, clearance holes must be in accordance with EN 50262 Table 1 and the entry device should be suitably secured.

 

 

 