南非CCG防爆接线盒(CCG Boxes for Hazardous Areas )
南非CCG防爆接线盒(CCG Boxes for Hazardous Areas )
南非CCG防爆接线盒(CCG Boxes for Hazardous Areas )

南非CCG防爆接线盒(CCG Boxes for Hazardous Areas )

参考价: 面议

具体成交价以合同协议为准
2022-01-06 13:15:41
420
产品属性
关闭
上海颐品自动化科技有限公司

上海颐品自动化科技有限公司

免费会员
收藏

组合推荐相似产品

产品简介

南非CCG防爆接线盒(CCG Boxes for Hazardous Areas )
上海颐品自动化,:

详细介绍

南非CCG防爆接线盒(CCG Boxes for Hazardous Areas )

CCG full product range


 
CCG Products are produced under the quality management system ISO9001-2000 standard underwritten by UL USA. CCG Products are internationally certified to British, CENELEC/ATEX, Chinese, South African IEC and Australian standards where applicable.
 

 

Junction Boxes
For Industrial / Mining and  Hazardous Areas

 

 
  
 
 Boxes for Commercial use
 CCG Utility Box General purpose junction box
For industrial applications
   
 CCG Foundation / Roof Entry Box 
For municipal and overhead single phase service connections
   
   
 Boxes for Hazardous Areas
 CCG 3 Way bottom entry box EExe, Exn, DIP, IP68
Industrial and hazardous areas junction box
   
 CCG 4 Way / Y Box EExe, Exn, DIP, IP68  
For use in hazardous areas and industrial electric installations
   

 

Boxes for use in commercial areas 
  
 
CCG Utility Box
General purpose junction box

Features and Benefits
•Connection box for industrial applications.
•Manufactured from impact corrosion and UV resistant glass reinforced polyester compound.
•Screw on lid provides ease of installation locked with a special locking key prevents 
  unauthorised tampering and ease of installation.
•No exposed metal parts.
•Dust and water proof to IP68 when used with CCG sealed glands.
•One box offers 1, 2, 3 or 4 way versatility (reduced stock holding).
•4 blanking plugs provided.
•No drilling or tapping of cable entries required.
•Internal earth continuity ring and earth stud provided.
•Mounting studs provided for DIN rail if using CCG terminal blocks (see leaflet No. T 010203).
 

 
 
Download Data Sheet
 
 
Standards and Certifications
ABS Marine APPROVAL
 
09-SG435709B-PDA
 
Australian
AS2380.1 1989 ANZEx 08.2001 
AS2380.6 1988 ANZEx 08.2001 
AS2380.9 1991 ANZEx 08.2001 
AS2236 1994 ANZEx 08.2001 
 
SABS/SANS/IEC
SANS/SABS 1222/IEC600529 S787/A718
Download Certification ANZEx 08.2001  
Download SABS S787/A718 CCG Utility Box
Download ABS 09-SG435709B-PDA
Download Permit

 

Boxes for use in commercial areas 
  
CCG Foundation / Roof Entry Box
For municipal and overhead service connections

CCG Foundation Box for municipal connections
Features and Benefits
•For municipal service connections.
•Manufactured from impact corrosion and UV resistant glass reinforced polyester compound.
•Screw-on lid provides ease of installation locked with a special key prevents
  unauthorised tampering.
•Integral cable gland and lid seal provide dust and waterproof seal.
•Knock-out holes provide for conduit entry at rear of box.
•Internal earth connector provided.

 

 
 
Download Data Sheet
  
 CCG Roof Entry Box for overhead service connections
Features and Benefits
•For overhead single phase service connections.
•Manufactured from non-conductive non-corrosive UV resistant glass
  reinforced polyester compound.
•Screw-on lid provides ease of installation locked with a special key prevents
  unauthorised tampering.
•Box is mounted through corrugated iron or asbestos type roof sheeting.
•Roof entry sealed by rubber bush.
•Terminal connectors and integral earth connector supplied with box.
 

 
 
Download Data Sheet 

 

Boxes for hazardous areas 
  
 
CCG 3 Way Bottom Entry Box EExe, Exn, DIP, IP68
Industrial and hazardous areas junction box

 
 
Features and Benefits
•3-way bottom entry Connection box for industrial and hazardous area lighting applications.
•Manufactured from impact corrosion and UV resistant glass reinforced polyester compound.
•Screw on lid provides ease of installation locked with a special locking key prevents 
  unauthorised tampering and ease of installation.
•No exposed metal parts.
•Dust and water proof to IP68 when used with CCG sealed glands.
•No drilling or tapping of cable entries required.
•Internal earth continuity and earth stud provided.
•Mounting stand-offs provided for DIN rail if using CCG terminal blocks (see leaflet No. T 010203).
 

 

 
Download Data Sheet
 
 
Standards and Certifications
Hazardous Area Classification
 
(100201-B only) 
 
IEC, SABS, AUS Ex, CNEx< Zone 1,2 21 and 22 Ex e IIC and DIP 
CENELEC / ATEX Catergory 2, Catergory 3, EEx e II 2 GD
 
ABS Marine APPROVAL
 
09-SG435709B-PDS
 
Australian
AS2380.1 1940 ANZEx 08.2001 
AS2380.6 1988 ANZEx 08.2001 
AS2380.9 1991 ANZEx 08.2001 
AS2236 1994 ANZEx 08.2001 
 
CENELEC / ATEX
EN50014 1997E DEMKO 01 ATEX 130324(Apparatus) 130515U(Unfinished) 
EN50019 2000E DEMKO 01 ATEX 130324(Apparatus) 130515U(Unfinished) 
EN50281-1-1-1 1999E DEMKO 01 ATEX 130324(Apparatus) 130515U(Unfinished) 
 
Chinese
GB3836.1.2000 CNEx09.0430x 
GB3836.3.2000 CNEx09.04430x 
GB12476.1.2000 CNEx09.0430x 
 
SABS/SANS/IEC
SANS/SABS 1213 S777/M132 
SANS/SABS 1031 S777/M132 
 
Impact Protection7 Joules
Ingress ProtectionIP66/67/68
Operating Temperature-30?C TO +130?C
Download Certification ANZEx 08.2001  
Download Certification AUS2395U  
Download Certification ATEX 130324  
Download Certification ATEX 130515U  
Download Certification CNEx09 0430X
Download Certification SABS S777/M132
Download Certification ABS 09-SG435709B-PDA
Download Permit

 

Boxes for use in hazardous areas 
  
 
CCG 4 Way / Y Box EExe, Exn, DIP, IP68
Industrial and hazardous areas junction box

 
CCG 4 Way Box IP68
Features and Benefits
•For use in surface hazardous areas and general industrial electrical installations.
•Manufactured from impact, corrosion and UV resistant glass reinforced polyester compound.
•High temperature resistance and anti-static properties (black boxes only).
•Red Fire Rated box for emergency circuits (Rated 750?C for 30 min.)
•Screw-on lid allows ease of installation locked with a special key prevents 
  unauthorised tampering.
•No exposed metal parts.
•One box gives 1, 2, 3 and 4 way versatility (reduced stock holding).
•4 blanking plugs provided.
•No drilling or tapping of entries required.
 

 

 CCG Box Blanking Plugs

 
Download Data Sheet
  
 CCG Y Box IP68
Features and Benefits
•Internal earth continuity ring and earth studs provided.
•DIN rail mounting studs are provided for use with CCG terminal blocks (see leaflet No. T 010203).
•Raised domed lid facilitates connections to be made outside of the box.
•If boxes are used in hazardous areas only approved Exe glands and Exe non-sparking terminals
  must be fitted.
•Dust and water tight to IP68 when fitted with CCG sealed glands.
•Can be buried for extended periods.
•Boxes with see through polycarbonate •?adapt-a lids••available on request.
•4 way H-boxes with parallel entries available on request.
 

 

 CCG Pole Mounting Bracket for 'Y' Box

 
Download Data Sheet
 
 
Standards and Certifications
Hazardous Area Classification
 
(100201-B only) 
 
IEC, SABS, AUS Ex, CNEx< Zone 1,2 21 and 22 Ex e IIC and DIP 
CENELEC / ATEX Catergory 2, Catergory 3, EEx e II 2 GD
 
ABS Marine APPROVAL
 
09-SG435709B-PDA
 
Australian
AS2380.1 1989 ANZEx 08.2001 
AS2380.6 1988 ANZEx 08.2001 
AS2380.9 1991 ANZEx 08.2001 
AS2236 1994 ANZEx 08.2001 
 
CENELEC / ATEX
EN50014 1997E DEMKO 01 ATEX 130324(Apparatus) 130515U(Unfinished) 
EN50019 2000E DEMKO 01 ATEX 130324(Apparatus) 130515U(Unfinished) 
EN50281-1-1-1 1999E DEMKO 01 ATEX 130324(Apparatus) 130515U(Unfinished) 
 
Chinese
GB3836.1.2000 CNEx09.0430x 
GB3836.3.2000 CNEx09.04430x 
GB12476.1.2000 CNEx09.0430x 
 
SABS/SANS/IEC
SANS/SABS IEC 60529 
SANS/SABS IEC 60079-7 
SANS/SABS IEC 60079-0 
SANS/SABS IEC 60079-15 
SANS/SABS IEC 61241-0 
SANS/SABS IEC 61241-1 
 
SAEx S/07/086x 
SAEx S/07/086x S777/M132 
SAEx S/07/086x S777/M132 
SAEx S/07/086x 
SAEx S/07/086x 
SAEx S/07/086x
Ingress ProtectionIP 66/67/68 (2m Cont.)
Ambient TempT70'C (-55'C < Tamb < 55'C)
Operating Temp65'C to +80'C
Download Certification ANZEx 08.2001  
Download Certification AUS2395U  
Download Certification ATEX 130324  
Download Certification ATEX 130515U  
Download Certification CNEx09 0430X
Download Certification SAEX S/07-086X
Download Permit
Download CCG Fire Survival Junction Box Test  
Download CCG Fire Survival Junction Box Test

 

中国区分销商:
上海颐品自动化科技有限公司

Shanghai Epin Automation Co.,Ltd.

Website:www.epinautomation。。com
:sales@epinautomation.com
*:

因为专业,所以放心!

 

上一篇:卧式暗装风机盘管机组产品选用要点 下一篇:消防排烟风机主管技术工程师应在总平面图上制作出管线及单线
热线电话 在线询价