南非CCG防爆非铠装格兰(CCG A2EX,Posi Grip,A2F cable gland)
Surface Use Group IIC unarmoured |
| | |
| A2EX EExde IIC Compression Gland for flexible cable For indoor / outdoor use and hazardous areas (A2 Type) |
| | |
| | Posi Grip EExe Compression Gland for flexible cable For use in highly corrosive and hazardous conditions |
| | |
| | A2EX FHC EExde IIC Compression Gland for flexible cable housed in conduit For use indoors and hazardous areas |
| | |
| | A2F EExde IIC Compression Gland for flexible cable For use indoors/outdoors and hazardous areas |
| | |
| | CCG BarrierTexTM F, Barrier EEx d Cable Gland for elastometric cable For use in potentially explosive atmospheres |
| |
| |
|
A2EX EExde IIC compression gland for unarmoured cable | |
Features and Benefits •For indoor/outdoor use and hazardous areas. (A2E Type) •Fitted with two specially formulated elastomeric seals. Inner seal seals on the cable sheath. Harder outer seal grips the cable, giving superior cable retention and IP rating •Manufactured from high quality brass and nickel plated. •Supplied with a polypropylene sealing gasket. |
| |
| |
| Technical Data | Type | A2EX | Gland Material | Brass (Nickel Plated), stainless steel and aluminium* | Seal Material | Thermoplastic Elastomer (Silicone on request) | Cable Type | Unarmoured | Sealing Area | Outer sheath | Optional Accessories | Locknut, Shroud, Earth Tag, Adaptor / Reducer |
| | Download Data Sheet | | | Download Assembly Instructions |
| Standards and Certifications | Hazardous Area Classification | | SANS/SABS IEC, AS/NZS IEC, CNEx | Zone 1, 2, 21 and 22 Exde IIC and DIP | CENELEC / ATEX | Category 2, Category 3, EExde II 2 GD | Compliance Code | Certification No. | CENELEC / ATEX | | EN50014:1997E | DEMKO 01 ATEX 130325X | EN50018:2000E | DEMKO 01 ATEX 130325X | EN50019:2000E | DEMKO 01 ATEX 130325X | EN50281-1-1:1999E | DEMKO 01 ATEX 130325X | SANS / SABS / IEC | | | SANS/SABS 1213 | SABS S/W 444UX | SANS/SABS IEC 60079-0 | 2000 | SABS S/W 444UX | SANS/SABS IEC 60079-1 | 2001 | SABS S/W 444UX | SANS/SABS IEC 60079-7 | 2001 | SABS S/W 444UX | SANS/SABS IEC 60529 | 1989 | SABS S/W 444UX | SANS/SABS IEC 61241.1.1 | 1999 | SABS S/W 444UX | AUSTRALIAN / NEW ZEALAND / IEC | AS/NZS IEC 60079-0 | 2000 | AUS Ex 03.3844X-1 | AS/NZS IEC 60079-1 | 2001 | AUS Ex 03.3844X-1 | AS/NZS IEC 60079-7 | 2001 | AUS Ex 03.3844X-1 | AS/NZS IEC 60529 | 1989 | AUS Ex 03.3844X-1 | AS/NZS IEC 61241.1.1 | 1999 | AUS Ex 03.3844X-1 | CHINESE | GB3638. 1-2000 part 1 | | CNEx09 0429U | GB3638. 2-2000 part 2 | | CNEx09 0429U | GB3638. 3-2000 part 3 | | CNEx09 0429U | GB12476. 1-2000 | | CNEx09 0429U |
| Ingress Protection | IP66/67/68 | Operating Temperature | -30?C TO +130?C | | Download Certification AUS Ex 03.3844X | | | Download Certification DEMKO 01 ATEX 130325X | | | Download Certification CNEx09 0429U | | | Download Permit No SANS/SABS 1213 | | | Download Certification SABS S/W444UX | | | ABS 09-SG435709-PDA | |
Special Conditions for Safe Use - X Glands must be used as part of a certified assembly in surface installations only Not for use on Exd enclosures that are larger than 2000cm3 volume in group IIC gases in zone 1 areas | |
| | | |
| Posi Grip EExe compression gland for unarmoured cable | | Features and Benefits •For use in highly corrosive and hazardous areas. •All brass parts encapsulated in a non-corrosive body. •Complete with a hard gripper seal, deluge proof O-ring and elastomeric inner seal for complete ingress protection IP68. •Supplied with a polypropylene gasket. | | | | | | Technical Data | Type | POSIGRIP | Gland Material | Brass encapsulated in Glass Reinforced Polyester/PBT | Seal Material | Thermoplastic Elastomer (silicone on request) | Cable Type | Unarmoured | Sealing Area | Outer sheath | Optional Accessories | Locknut |
| | Download Data Sheet | | | Download Assembly Instructions |
| Standards and Certifications | Hazardous Area Classification | IEC, SABS & AUS Ex, CNEx | | | Zone 1, 2, 21and 22 Exe IIC and DIP | CENELEC / ATEX | | | Category 2, Category 3, EExe II 2 GD | | Compliance Code | | | Certification No. | CENELEC / ATEX | | | | EN50014:1997E | | | DEMKO 01 ATEX 130325X | EN50019:2000E | | | DEMKO 01 ATEX 130325X | EN50281-1-1:1999E | | | DEMKO 01 ATEX 130325X | SANS / SABS / IEC | | | | SANS/SABS 1213 | | SABS S/W 458U | SANS/SABS IEC 60079-0 | 2000 | | SABS S/W 458U | SANS/SABS IEC 60079-7 | 2001 | | SABS S/W 458U | SANS/SABS IEC 60529 | 1989 | | SABS S/W 458U | SANS/SABS IEC 61241.1.1 | 1999 | | SABS S/W 458U | AUSTRALIAN | | | | AS 2380.6 | | | AUS Ex 2404U | AS 1939 | | | AUS Ex 2404U | NSW MDA | | | Exe 3171 | CHINESE | | | GB3638. 1-2000 | | CNEx09 0429U | GB3638. 3-2000 | | CNEx09 0429U | GB12476.1-2000 | | CNEx09 0429U |
| Ingress Protection | IP66/67/68 | Operating Temperature | -30?C to +130?C | | Download Certification AUS Ex 2404U | | | Download Certification DEMKO 01 ATEX 130325X | | | Download Certification CNEx09 0429U | | | Download Permit No SANS/SABS 1213 | | | Download Certification SABS S/W458U | | | ABS 09-SG435709-PDA | |
| |
|
|
| | | |
| A2EX FHC EExde IIC compression gland for unarmoured cable housed in conduit | | Features and Benefits •For indoor/outdoor use and hazardous areas. (A2E Type) •For use with all types of unarmoured cable housed in rigid or flexible conduit. •Fitted with two specially formulated elastomeric seals. Inner seal seals on the cable sheath. Harder outer seal grips the cable, giving superior cable retention and IP rating •Fitted with a rotating female connection for connection to conduit. •Manufactured from high quality brass and nickel plated and stainless steel. •Supplied with a polypropylene sealing gasket. | | | | | | Technical Data | Type | A2EX FHC | Gland Material | Brass (Nickel Plated), Stainless Steel | Seal Material | Thermoplastic Elastomer (Silicone on request) | Cable Type | Unarmoured in Conduit | Sealing Area | Inner sheath | Optional Accessories and Tools | Locknut, Shroud, Earth Tag, Adaptor / Reducer |
| | Download Data Sheet | | | Download Assembly Instructions |
| Standards and Certifications | Hazardous Area Classification | SANS / SABS IEC | Zone 1, 2, 21and 22 Eexde IIC and DIP | CENELEC / ATEX | Category 2, Category 3, EExde II 2 GD | Compliance Code | Certification No. | CENELEC / ATEX | EN50014:1997E | | DEMKO 01 ATEX 130325X | EN50018:2000E | | DEMKO 01 ATEX 130325X | EN50019:2000E | | DEMKO 01 ATEX 130325X | EN50281-1-1:1999E | | DEMKO 01 ATEX 130325X | SANS / SABS / IEC | | | SANS/SABS 1213, SABS 1031 | SABS S/W 443UX | SANS/SABS IEC 60079-0 | 2000 | SABS S/W 443UX | SANS/SABS IEC 60079-1 | 2001 | SABS S/W 443UX | SANS/SABS IEC 60079-7 | 2001 | SABS S/W 443UX | SANS/SABS IEC 60529 | 1989 | SABS S/W 443UX | SANS/SABS IEC 61241.1.1 | 2000 | SABS S/W 443UX |
|
| Ingress Protection | IP66/67/68 | Operating Temperature | -30?C TO +130?C | | Download Certification DEMKO 01 ATEX 130325X | | | | Download Permit No SANS/SABS 1213 | | | | Download Certification SABS S/W443UX | | | | ABS 09-SG435709-PDA | |
Special Conditions for Safe Use - X Glands must be used as part of a certified assembly in surface installations only. Not for use on Exd enclosures that are larger than 2000cm3 volume in group IIC gases in zone 1 areas. | |
|
|
| | | |
| A2F EExde IIC compression gland for FLEXIBLE CABLE | | Features and Benefits •For indoor/outdoor use and hazardous areas. •Fitted with specially formulated elastomeric displacement seal, giving superior cable retention, explosion protection and IP rating. •Manufactured from high quality brass and nickel plated. •Supplied with a polypropylene or neoprene sealing gasket. | | | | | | Technical Data | Type | A2F | Gland Material | Brass (Nickel Plated) | Seal Material | Thermoplastic Elastomer (Silicone on request) | Cable Type | Unarmoured | Sealing Area | Outer sheath | Optional Accessories and Tools | Locknut, Shroud, Earth Tag, Adaptor / Reducer |
| | Download Data Sheet | | | Download Assembly Instructions |
| Standards and Certifications | Hazardous Area Classification | CENELEC / ATEX | Category 2, Category 3, EExde II 2 GD | | | Compliance Code | Certification No. | CENELEC / ATEX | EN60079-0 2004 | | EPSILON 06 ATEX 2066X | EN60079-1 2004 | | EPSILON 06 ATEX 2066X | | | | | | | | | | | | | | | | | | | | | | | | | | |
| Ingress Protection | IP66/67/68 | Operating Temperature | -30?C TO +130?C | | Download Certification EPSILON 06 Atex 2066 | | |
| Download SAEx S/08-517X CCG A2F/A2FX Cable Gland | | |
| Download CNEx 09.0717U | | |
Special Conditions for Safe Use - X Glands must be used as part of a certified assembly in surface installations only. Not for use on Exd enclosures that are larger than 2000cm3 volume in group IIC gases in zone 1 areas. | |
|
|
| | | |
| BarrierTex F Barrier EExd Cable Gland for elastometric, unarmoured cable | | Features and Benefits •Precision manufactured from high quality brass and nickel plated. •Provides a barrier seal between the individual cores of the cable. •Inspectable compound and flameproof chamber. •Prevents explosive gasses propagating through a cable. •Prevents gas and moisture migrating through a cable. | | | | | | Technical Data | Type | BarrierTex F | Gland Material | Brass (Nickel Plated), Stainless Steel, Bronze | Seal Material | CCG FR308 or ST574 compound. Thermoplastic elastomer | Cable Type | Unarmoured cable | Sealing Area | Inner compound barrier and outer sheath |
| | Download Data Sheet | | | Download Assembly Instructions |
| Standards and Certifications | Hazardous Area Classification | | SANS/SABS IEC, AS/NZS IEC | Zone 1, 2, 21and 22, Exe, Exd I/IIC Ex tD A21 | CENELEC / ATEX | Ex tD A21, Exd I/IIC, Exe I/IIC and DIP | Compliance Code | Certification No. | CENELEC / ATEX | | EN60079-0 2006 | SIRA 07 ATEX 1044X | EN60079-1 2004 | SIRA 07 ATEX 1044X | EN60079-7 2003 | SIRA 07 ATEX 1044X | EN61241-0 2006 | SIRA 07 ATEX 1044X | SANS / SABS / IEC | | | SANS 808 | SAEx MS/06-425X | SANS/SABS IEC 60079-0 | 2006 | SAEx MS/06-425X | SANS/SABS IEC 60079-1 | 2004 | SAEx MS/06-425X | SANS/SABS IEC 60079-7 | 2003 | SAEx MS/06-425X | SANS/SABS IEC 61241-0 | 2005 | SAEx MS/06-425X | SANS/SABS IEC 61241-1 | 2005 | SAEx MS/06-425X | SANS/SABS IEC 60529 | 2001 | SAEx MS/06-425X | AUSTRALIAN / NEW ZEALAND / IEC | IEC 60079-0 | 2004 | ANZEx 07.4045X | IEC 60079-1 | 2003 | ANZEx 07.4045X | IEC 60079-7 | 2001 | ANZEx 07.4045X | IEC 61241-0 | 2004 | ANZEx 07.4045X | IEC 61241.1 | 2004 | ANZEx 07.4045X |
| Ingress Protection | IP66/67/68 (2m cont.) | Operating Temperature | -20?C TO +80?C | | Download Certification ITACS ANZEx 07.4045X | | | Download Certification Sira 07ATEX1044X | | | Download Certification SAEX MS06-425X (R6) | | | ABS 09-SG435709-PDA | |
| |
|
|
中国区分销商:
上海颐品自动化科技有限公司
Shanghai Epin Automation Co.,Ltd.
Website:www.epinautomation。。com
:sales@epinautomation.com
*:
因为专业,所以放心!