南非CCG铠装防爆格兰(CCG FLP-TR, FLP HOSE cable gland)
Underground and Surface Use Group I and IIC unarmoured |
| | |
| FLP-TR EExd I / IIC Compression Gland for use with flexible cable For use in hazardous areas |
| | |
| | FLP Hose EExd I / IIC Compression Gland for use with flexible cable For use in hazardous areas |
| | |
Underground and Surface Use Group I and IIC armoured |
| | FLP EExd I / IIC Captive Component Gland MAC - Multi Armour Cone For use in hazardous areas |
| | |
| | Armortex EExd I / IIC Gland MAC - Multi Armour Cone For use in hazardous areas |
| |
| |
|
FLP-TR EExd I / IIC compression gland for use with unarmoured cable | |
Features and Benefits •Fitted with specially formulated captive elastomeric seals, built-in safety. •No loose parts that can get lost. •Provided with an extra hard gripper seal to grip cable. •Manufactured from high quality brass, nickel plated and stainless steel. •Complete with an orange thread cap/safety gauge for correct gland selection. |
| |
| |
| Technical Data | Type | FLP TR | Gland Material | Brass (Nickel Plated), Stainless Steel | Seal Material | Thermoplastic Elastomer | Cable Type | Unarmoured TRS | Sealing Area | Outer sheath | Optional Accessories | Shroud, Adaptor/Reducer |
| | Download Data Sheet | | | Download Assembly Instructions |
| Standards and Certifications | Hazardous Area Classification | | SANS/SABS IEC | Zone 1, 2, 21and 22 Exd I / IIC, Exe I / IIC and DIP | CENELEC / ATEX | Category 2, Category 3, EExde I / II 2 GD, EExd I M2 | Compliance Code | Certification No. | CENELEC / ATEX | | EN50014:1997E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | EN50018:2000E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | EN50019:2000E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | EN50281-1-1:1999E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | SANS / SABS / IEC | | | SANS 808 | SABS MS/W 454U | SANS/SABS IEC 60079-0 | 2000 | SABS MS/W 454U | SANS/SABS IEC 60079-1 | 2001 | SABS MS/W 454U | SANS/SABS IEC 60079-7 | 2001 | SABS MS/W 454U | SANS/SABS IEC 60529 | 1989 | SABS MS/W 454U | SANS/SABS IEC 61241.1.1 | 1999 | SABS MS/W 454U | CHINESE | GB3638. 1-2000 part 1 | | CNEx09 0428U | GB3638. 2-2000 part 2 | | CNEx09 0428U | GB3638. 3-2000 part 3 | | CNEx09 0428U | GB12476. 1-2000 | | CNEx09 0428U |
| Ingress Protection | IP66/67/68 | Operating Temperature | -30?C to + 130?C | | Download ECS 06 ATEX 2044 FLP TR Cable Gland | | | Download Certification DEMKO 01 ATEX 130325X | | | Download Certification CNEx09 0428U | | | Download Permit No SANS 808 | | | Download Certification SABS MS/W454U | |
Special Conditions for Safe Use - X Glands that incorporate a seal with an uncompressed height of less than 20mm shall not be used with EEX d IIC apparatus that has a volume in excess of 2000cc. If mounted in flame proof enclosures, make sure that at least threads are engaged and that the depth of engagement of enclosures smaller than 100 cm3 are at least 5mm and for enclosures larger than 100 cm3 at least 8mm. | |
| |
| |
|
FLP Hose EExd I / IIC compression gland for use with unarmoured cable | |
Features and Benefits •Fitted complete with a specially formulated elastomeric captive seal for built-in safety. •Complete with a spigot to attach a hose for cable protection. •Manufactured from high quality brass, nickel plated and stainless steel. •Complete with an orange thread cap / safety gauge for correct gland selection. |
| |
| |
| Technical Data | Type | FLP Hose | Gland Material | Brass (Nickel Plated), Stainless Steel | Seal Material | Thermoplastic Elastomer | Cable Type | Unarmoured TRS | Sealing Area | Outer sheath | Optional Accessories | Shroud, Adaptors/Reducers |
| | Download Data Sheet | | | Download Assembly Instructions |
| Standards and Certifications | Hazardous Area Classification | | SANS/SABS IEC | Zone 1, 2, 21and 22 Exd I / IIC, Exe I / IIC and DIP | CENELEC / ATEX | Category 2, Category 3, EExde I / II 2 GD, EExd I M2 | Compliance Code | Certification No. | CENELEC / ATEX | | EN50014:1997E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | EN50018:2000E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | EN50019:2000E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | EN50281-1-1:1999E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | SANS / SABS / IEC | | | SANS 808 | SABS MS/W 453U | SANS/SABS IEC 60079-0 | 2000 | SABS MS/W 453U | SANS/SABS IEC 60079-1 | 2001 | SABS MS/W 453U | SANS/SABS IEC 60079-7 | 2001 | SABS MS/W 453U | SANS/SABS IEC 60529 | 1989 | SABS MS/W 453U | SANS/SABS IEC 61241.1.1 | 1999 | SABS MS/W 453U | CHINESE | GB3638. 1-2000 part 1 | | CNEx09 0428U | GB3638. 2-2000 part 2 | | CNEx09 0428U | GB3638. 3-2000 part 3 | | CNEx09 0428U | GB12476. 1-2000 | | CNEx09 0428U |
| Ingress Protection | IP66/67/68 | Operating Temperature | -30?C to + 130?C | | Download ECS 06 ATEX 2044 FLP HOSE Cable Gland | | | Download Certification DEMKO 01 ATEX 130325X | | | Download Certification CNEx09 0428U | | | Download Permit No SANS 808 | | | Download Certification SABS MS/W453U | | |
Special Conditions for Safe Use - X Glands that incorporate a seal with an uncompressed height of less than 20mm shall not be used with EEX d IIC apparatus that has a volume in excess of 2000cc. If mounted in flame proof enclosures, make sure that at least threads are engaged and that the depth of engagement of enclosures smaller than 100 cm3 are at least 5mm and for enclosures larger than 100 cm3 at least 8mm. | |
| | | |
| FLP EExd I / IIC captive cone gland MAC - Multi Armour Cone | | Features and Benefits •Two part handling, freely rotating captive cone for earth continuity and armour clamping. •Factory fitted with a specially formulated elastomeric seal provides built-in safety. •No loose parts that can get lost. •Manufactured from high quality brass, nickel plated and stainless steel. •Complete with an orange thread cap / safety gauge for correct gland selection. | | | | | | Technical Data | Type | FLP | Gland Material | Brass (Nickel Plated), Stainless Steel | Seal Material | Thermoplastic Elastomer | Cable Type | Steel Wire, Braid, Tape Armour | Armour Clamping | Captive Cone and Cone Ring | Sealing Area | Inner sheath | Optional Accessories | Shroud, Adaptor/Reducer |
| | Download Data Sheet | | | Download Assembly Instructions |
| Standards and Certifications | Hazardous Area Classification | | SANS/SABS IEC | Zone 1, 2, 21and 22 Exd I / IIC, Exe I / IIC and DIP | CENELEC / ATEX | Category 2, Category 3, EExde I / II 2 GD, EExd I M2 | Compliance Code | Certification No. | CENELEC / ATEX | | EN50014:1997E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | EN50018:2000E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | EN50019:2000E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | EN50281-1-1:1999E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | SANS / SABS / IEC | | | SANS 808 | SABS MS/W 455U | SANS/SABS IEC 60079-0 | 2000 | SABS MS/W 455U | SANS/SABS IEC 60079-1 | 2001 | SABS MS/W 455U | SANS/SABS IEC 60079-7 | 2001 | SABS MS/W 455U | SANS/SABS IEC 60529 | 1989 | SABS MS/W 455U | SANS/SABS IEC 61241.1.1 | 1999 | SABS MS/W 455U | CHINESE | GB3638. 1-2000 part 1 | | CNEx09 0428U | GB3638. 2-2000 part 2 | | CNEx09 0428U | GB3638. 3-2000 part 3 | | CNEx09 0428U | GB12476. 1-2000 | | CNEx09 0428U |
| Ingress Protection | IP66/67/68 | Operating Temperature | -30?C to + 130?C | | Download ECS 06 ATEX 2044 FLP Cable Gland | | | Download Certification DEMKO 01 ATEX 130325X | | | Download Certification CNEx09 0428U | | | Download Permit No SANS 808 | | | Download Certification SABS W455U | |
Special Conditions for Safe Use - X Glands that incorporate a seal with an uncompressed height of less than 20mm shall not be used with EEX d IIC apparatus that has a volume in excess of 2000cc. If mounted in flame proof enclosures, make sure that at least threads are engaged and that the depth of engagement of enclosures smaller than 100 cm3 are at least 5mm and for enclosures larger than 100 cm3 at least 8mm. | |
|
|
| | | |
| Armortex EExd I / IIC Gland MAC - Multi Armour Cone | | Features and Benefits •Nickel plated brass / stainless steel gland for steel wire, tape, braided, aluminium, armoured cable •No need to change seals or reverse cones or cone rings to accommodate different types of armoured cable. •Captive cone and cone ring ensures no loose parts during assembly. •Extra long captive explosion proof seal ensures built in safety. •Armour clamp components can be inspected after installation. •Gland can be used on Exd enclosures greater than 2 litres volume. | | | | | | Technical Data | Type | ARMORTEX | Gland Material | Brass (Nickel Plated), Stainless Steel | Seal Material | Thermoplastic Elastomer | Cable Type | Steel Wire, Braid, Tape Armour | Armour Clamping | Multi Armour Cone and Cone Ring | Sealing Area | Inner and outer sheath | Optional Accessories and Tools | Shroud, Earth Tag, Adaptor / Reducer | |
| | Download Data Sheet | | | Download Assembly Instructions |
| Standards and Certifications | Hazardous Area Classification | | SANS/SABS IEC | Zone 1, 2, 21and 22 Exd I / IIC, Exe I / IIC and DIP | CENELEC / ATEX | Category 2, Category 3, EExde I / II 2 GD, EExd I M2 | Compliance Code | Certification No. | CENELEC / ATEX | | EN50014:1997E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | EN50018:2000E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | EN50019:2000E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | EN50281-1-1:1999E | DEMKO 01 ATEX 130325X EPSILON 06 ATEX 2044 | SANS / SABS / IEC | | | SANS 808 | SABS MS/W446U | SANS/SABS IEC 60079-0 | 2000 | SABS MS/W446U | SANS/SABS IEC 60079-1 | 2001 | SABS MS/W446U | SANS/SABS IEC 60079-7 | 2001 | SABS MS/W446U | SANS/SABS IEC 60529 | 1989 | SABS MS/W446U | SANS/SABS IEC 61241.1.1 | 1999 | SABS MS/W446U | CHINESE | GB3638. 1-2000 part 1 | | CNEx09 0428U | GB3638. 2-2000 part 2 | | CNEx09 0428U | GB3638. 3-2000 part 3 | | CNEx09 0428U | GB12476. 1-2000 | | CNEx09 0428U |
| Ingress Protection | IP66/67/68 | Operating Temperature | -30?C to + 130?C | | Download ECS 06 ATEX 2044 Armortex Cable Gland | | | Download Certification DEMKO 01 ATEX 130325X | | | Download Certification CNEx09 0428U | | | Download Permit No SANS 808 | | | Download Certification SABS MS/W446U | |
Special Conditions for Safe Use - X Glands that incorporate a seal with an uncompressed height of less than 20mm shall not be used with EEX d IIC apparatus that has a volume in excess of 2000cc. If mounted in flame proof enclosures, make sure that at least threads are engaged and that the depth of engagement of enclosures smaller than 100 cm3 are at least 5mm and for enclosures larger than 100 cm3 at least 8mm. | |
|
|
中国区分销商:
上海颐品自动化科技有限公司
Shanghai Epin Automation Co.,Ltd.
Website:www.epinautomation。。com
:sales@epinautomation.com
*:
因为专业,所以放心!