CMP E2FU cable gland CMP Cable gland(E2FU Tri-Star Flameproof)

供应商:
上海颐品自动化科技有限公司
企业类型:
代理商

产品简介

上海颐品自动化代理CMP E1FX Tri-Star Flameproof Exd Cable Gland
上海颐品自动化代理CMP E1FX Tri-Star Flameproof Exd Cable Gland
上海颐品自动化代理CMP Cable Gland 【:】

详细信息

CMP E2FU Tri-Star Flameproof Ex d, Increased Safety Ex e and Restricted Breathing Ex nR Cable Gland

CMP Type E2FU Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) indoor and outdoor cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas with all types of Lead Covered or Lead Sheathed and armoured cable.

All CMP Cable Glands are EMC Tested.

This cable gland provides a Flameproof seal on the cable inner lead covering and in addition the gas tight seal has been tested to prove compatibility with Restricted Breathing equipment. The cable gland allows mechanical cable retention and earth continuity via the cable armour termination, and also earth bonding of the inner Lead Covering or Lead Sheath. Separate tightening actions for the inner Displacement Seal and the Armour Termination afford maximum control over the pressure applied to the cable inner lead covering, and also allows the effectiveness of the gas tight seal to be tested. A detachable universal armour cone and AnyWay clamping ring arrangement facilitates remote make off and enables the cable to be disconnected from the equipment. An environmental / load retention seal is provided on the cable outer sheath.

The CMP E2FU Tri-Star Cable Gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14.


Cable Gland Selection Table

Cable Gland SizeAvailable Entry Threads "C"Min Thread Length "E"Lead Sheath Diameter "A"Overall Cable Diameter "B"Armour Range +Across Flats "D"Across Corners "D"Protrusion Length "F"Ordering Reference (Brass Metric) #Shroud Ref*Cable Gland Weight (Kgs)
StandardOptionMinMaxMinMaxGrooved ConeStepped ConeMaxMax
MetricNPTNPTMinMaxMinMax
20S/16M201/2"3/4"15.03.18.66.113.20.40.80.81.024.026.458.520S16E2FU1RAPVC040.163
20SM201/2"3/4"15.06.111.69.515.90.40.80.81.2524.026.458.520SE2FU1RAPVC040.163
20M201/2"3/4"15.06.513.912.520.90.61.00.81.2530.533.660.520E2FU1RAPVC060.217
25SM253/4"1"15.011.119.914.022.00.61.11.251.637.541.367.525SE2FU1RAPVC090.345
25M253/4"1"15.011.119.918.226.20.61.11.251.637.541.367.525E2FU1RAPVC090.345
32M321"1 1/4"15.017.026.223.733.90.61.21.62.046.050.669.532E2FU1RAPVC110.484
40M401 1/4"1 1/2"15.022.032.127.940.40.61.21.62.055.060.578.040E2FU1RAPVC150.700
50SM501 1/2"2"15.029.538.135.246.70.61.52.02.560.066.075.550SE2FU1RAPVC180.800
50M502"2 1/2"15.035.644.040.453.10.81.52.02.570.077.080.550E1FU1RAPVC210.830
63SM632"2 1/2"15.040.149.945.659.40.81.52.02.575.082.591.563SE2FU1RAPVC231.415
63M632 1/2"3"15.047.255.954.665.90.81.52.02.580.088.092.063E2FU1RAPVC251.514
75SM752 1/2"3"15.052.861.959.072.10.81.52.02.589.097.999.075SE2FU1RAPVC282.199
75M753"3 1/2"15.059.167.966.778.50.81.52.53.099.0108.9102.075E2FU1RAPVC302.770
90M903"3 1/2"15.066.679.976.290.40.81.53.03.5114.0125.4120.090E2FU1RAPVC324.350
100M100 -15.076.090.986.1101.50.81.53.154.0123.0135.3148.0100E2FU1RALSF334.750
115M115--15.086.097.9101.5110.30.81.53.154.0133.4146.7169.0115E2FU1RALSF347.300
130M130--15.097.0114.9114.2123.30.81.53.154.0146.1160.7183.0130E2FU1RALSF358.600
Dimensions are displayed in millimetres unless otherwise stated

NOTE: *CMP SOLO LSF Halogen Free Shrouds also available on request. + Alternative armour clamping range available for non-standard armour sizes. # Other thread forms, materials and finishes are available. IEC Ex, ATEX & CSA hazardous area certification marking included as standard. Please consult CMP for any other requirements.

TypeCMP E2FU Tri-Star Cable gland
Design SpecificationBS 6121:Part 1:1989, EN 50262:1999
ATEX Certification DetailSIRA06ATEX1097X, SIRA07ATEX4326X
ATEX Code of Protection CategoryATEX ATEX Approved II 2 GD, Ex d IIC, Ex e II, Ex tD A21 IP66, ATEX ATEX Approved II 3 G Ex nR II
ATEX Compliance StandardsEN 60079-0, EN 60079-1, EN 60079-7, EN 60079-15, IEC 61241-0, EN 61241-1
IEC Ex Certification DetailIECEx SIR 06.0043X
IEC Ex Code of Protection CategoryEx d IIC, Ex e II, Ex nR II, Ex tD A21 IP66, Ex d I,
Ex e I
IEC Ex Compliance StandardsIEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 60079-15, IEC 61241-0, IEC 61241-1
Continuous Operating Temperature-60°C to +130°C
Ingress Protection RatingIP66, IP67, IP68 #
Cable Gland MaterialBrass, Electroless Nickel Plated Brass, Stainless Steel, Aluminium
Seal MaterialCMP SOLO LSF Thermoplastic Elastomer
Cable TypeLead Sheathed & Single Wire Armour (LC/SWA), Lead Sheathed & Aluminium Wire Armour (LC/AWA), Lead Sheathed & Wire Braid Armour (LC/SWB), Lead Sheathed & Pliable Wire Armour (LC/PWA), Lead Sheathed & Steel Tape Armour (LC/STA), Lead Sheathed & Aluminium Strip Armour (LC/ASA)
Armour ClampingReversible Armour Cone & AnyWay Universal Clamping Ring
Sealing TechniqueCMP Inner Displacement Seal & Unique CMP "LRS" TM Outer Load Retention Seal
Sealing Area(s)Cable Inner Lead Covering & Cable Outer Sheath

 

CMP Cable Glands - ATEX Ex Flameproof Gland【:】

【EPIN AUTOMATION】 【上海颐品自动化】【EPIN AUTOMATION】【上海颐品自动化】

CMP Cable Glands - A2F Ex Flameproof Cable Gland for Unarmoured and Braided Cables
CMP Cable Glands- A2FFC Ex Flameproof Conduit Gland for Unarmoured Cables in Flexible Metal Conduit
CMP Cable Glands - A2FRC Ex Conduit Gland for Unarmoured Cables in Rigid or Flexible Metallic Conduit
CMP Cable Glands - E1FU Ex Flameproof Cable Gland for all types of Armoured Cables
CMP Cable Glands - E1FW Ex Flameproof Cable Gland for Single Wire Armour (SWA) Cables
CMP Cable Glands - E1FX Ex Flameproof Cable Gland for Braided, PWA, Strip Armour, STA Cables
CMP Cable Glands - E2FU Ex Flameproof Cable Gland for Lead Covered, Lead Sheathed and Armoured Cables
CMP Cable Glands - E2FW Ex Flameproof Cable Gland for Lead (LC) or (LS) and Single Wire Armour (SWA) Cables
CMP Cable Glands- E2FX Ex Flameproof Gland for Lead (LC) or LS and Braided, PWA, Strip Armour, or STA Cable

CMP Cable Glands - ATEX Ex Increased Safety Gland-Oil Gas and Petrochemical

【EPIN AUTOMATION】 【:】【EPIN AUTOMATION】【EPIN AUTOMATION】
CMP Cable Glands - A2Pe (Ex e) Gland for Un-armoured, Screened Flexible Cable
CMP Cable Glands - C2K Ex Gland for Armoured Cables (Ex e)
CMP Cable Glands - CWe Gland for Single Wire Armoured (SWA) Cables (Ex e)
CMP Cable Glands - CXe Gland for Braided and Armoured (SWA) Cables (Ex e)
CMP Cable Glands - SS2KTA Gland for Steel Tape Armour Cables (Ex e)

【EPIN AUTOMATION】 【EPIN AUTOMATION】【EPIN AUTOMATION】【EPIN AUTOMATION】
CMP Cable Glands - ATEX Ex Barrier Gland-?Oil Gas and Petrochemical

CMP Barrier Gland - PX2K Ex Cable Gland for Armoured Cables (Ex d, Ex e, Ex nR)
CMP Barrier Glands - PX2KPB Ex Cable Gland for Lead (LS), Armoured Cables (Ex d, Ex e, Ex nR)
CMP Barrier Glands - PX2KW Ex Cable Glands for Armoured Cables (Ex d, Ex e, Ex nR)
CMP Barrier Glands - PXRC Ex Conduit Gland for Unarmoured Cables (Ex d, Ex e, Ex nR)
CMP Barrier Glands - PXSS2K Ex Cable Gland for Unarmoured Cables (Ex d, Ex e, Ex nR)

【EPIN AUTOMATION】 【EPIN AUTOMATION】【EPIN AUTOMATION】【EPIN AUTOMATION】

CMP Cable Glands - A2, BW, CW, E1W, E2W, SS2KGP Gland Kits

CMP Cable Glands - A2 Gland for Unarmoured Cables
CMP Cable Glands - A2 LSF Gland for Unarmoured Cables
CMP Cable Glands - A2 200 Gland for Unarmoured Cables
CMP Cable Glands - A2DG Dome Top Gland for Unarmoured Cables
CMP Cable Glands - A2RC Conduit Gland for Unarmoured Cables in Rigid Conduit
CMP Cable Glands - B323 Insulated Gland for Single Wire Armour (SWA) Cables
CMP Cable Glands - B347 Insulated Gland with Integral Earth for Single Wire Armour (SWA) Cables
CMP Cable Glands - B324 Insulated Gland with Integral Earth for Single Wire Armour (SWA) Cables
CMP Cable Glands - B348 Insulated Gland for Single Wire Armour (SWA) Cables
CMP Cable Glands - B327 Insulated Gland with Integral Earth for Screened and Single Wire Armour (SWA) Cables
CMP Cable Glands - B350 Insulated Gland for Screened and Single Wire Armour (SWA) Cables
CMP Cable Glands - B367 Insulated Gland with Integral Earth for Wire Braid, PWA, Strip Armour or STA Cables
CMP Cable Glands - B368 Insulated Gland for Wire Braid, PWA, Strip Armour or STA Cable
CMP Cable Glands - BW Gland for Single Wire Armour (SWA) Cables

【EPIN AUTOMATION】 【EPIN AUTOMATION】【:】【EPIN AUTOMATION】

CMP Cable Glands - BW SOLO LSF Gland for Single Wire Armour (SWA) Cables
CMP Cable Glands - BWL Heavy Duty Gland for Single Wire Armour (SWA) Cables
CMP Cable Glands - BWL CIEL Gland with Integral Earth for Single Wire Armour (SWA) Cables
CMP Cable Glands - C2KGP Gland for SWA, Wire Braid Armour, Strip Armour, PWA, STA Cables
CMP Cable Glands - CW Cable Gland for Single Wire Armour (SWA) Cables
CMP Cable Glands - CW CIEL Gland with Integral Earth for Single Wire Armour (SWA) Cables
CMP Cable Glands - CW SOLO LSF Gland for Single Wire Armour (SWA) Cables
CMP Cable Glands - CX Gland for Wire Braid Armour, Strip Armour, PWA and STA Cables
CMP Cable Glands - E1U Universal Gland for all Armoured Cables
CMP Cable Glands - E1W Gland for Single Wire Armour (SWA) Cables
CMP Cable Glands - E1W CIEL Gland with Integral Earth for Single Wire Armour (SWA) Cables
CMP Cable Glands - E1W SOLO LSF Gland for Single Wire Armour (SWA) Cables
CMP Cable Glands - E1X Gland for Wire Braid Armour, Strip Armour, PWA and STA Cables
CMP Cable Glands - E2U Universal Gland for all Lead Sheathed and Armoured Cables

【EPIN AUTOMATION】 【EPIN AUTOMATION】【EPIN AUTOMATION】【EPIN AUTOMATION】

CMP Cable Glands - E2W Gland for Lead Sheathed and Single Wire Armour (SWA) Cables
CMP Cable Glands - E2W CIEL Gland with Integral Earth for Lead (LC/LS) and SWA Cables
CMP Cable Glands - E2X Gland for Lead Sheathed, Wire Braid Armour, Strip Armour, PWA, STA Cables
CMP Cable Glands - SS2KGP Gland for Unarmoured Cables
CMP Cable Glands - SS2KGP/PB Gland for Lead Sheathed Unarmoured and STA Cables

【EPIN AUTOMATION】 【:400-855-251】【EPIN AUTOMATION】【EPIN AUTOMATION】